Solenoid Valves

D Series Solenoid Valve

Part Number: D3012
D2016-C204_Product_Full_Width_1000x750
Image is of similar product

PRODUCT DESCRIPTION:

D Series Solenoid Valves deliver a wide range of Cv (Kv) values and maximum operating pressures. The D Series is also available in multiple body materials, seal materials, coil constructions, voltages, and wattages.

LEAD TIME:

15 days
CE ROHS Gems Compliant CSA

Features

  • MOPD: 900 PSI (62 Bar)
  • Cv Range: 0.045 to 0.880 (Kv Range: 0.038 to 0.748)
  • 10 Watts
Sku
D3012
CFGType
ABCD
Model
D Valve
MOPD
150 psi
Maximum Back Pressure
-
Body CV
0.11
Stop CV
0.11
Power
10 Watts
Body Orifice
5/64"
Stop Orifice
5/64"
Body Style
Grommet
Weight
0.073

Solenoid Valve Selection Guide

Format .pdf
Size 410 KB

Gems Sensors Instructions, A, B, & D Series Torque

Format .pdf
Size 253 KB

Gems Sensors Instructions, D Series Spanner Tool

Format .pdf
Size 189 KB

Gems Sensors Catalog, D Series Valve

Format .pdf
Size 3 MB
Does Gems Sensors do customized valves?

Yes, for qualified OEM applications. Together with your design team, Gems’ engineers can customize the best solution for your application.

What is the difference in the coil classifications?

Gems have 3 class options, each having a different maximum operating temperature. Be aware that valves left on for 5 to 10 minutes will self-heat. A typical 6 watt “A” valve will self-heat to 60°C while a 10 watt “D” valve will self-heat to 90°C Class B 266°F / 130°C Class F 311°F / 155°C Class H 365°F / 180°C

What is the standard operating temperature on a Gems solenoid valve?

-40°F to 212°F / -40°C to 100°C Cryogenic valves are rated to -320°F / -196°C

What is a latching valve?

A latching valve is designed to allow the valve to stay either open or closed without continuous power.

What does MOPD stand for?

Maximum opening pressure difference across the valve. Gems solenoid valves range from 0 to 1000 PSI

What is an isolation valve?

A diaphragm is used to isolate media from the over seat parts of the valve, reducing media contact with the valves internal components. This is suitable for aggressive liquids or gases and helps reduce the risk of media contamination.