Gems Sensors Spacer
Message
 
Loading...
 ELS-1100FLG Series

Flange Mounting for Installation Without Threaded Holes 

ELS1100 FLG 

 

Quick Specs...

  • Small Size
  • Economically Priced
  • Build-in, Solid-State Electronics
  • No Moving Parts
  • Simple, One-Unit Installation


 

 

  Overview    Specifications    Dimensions    Related Info   
               

Overview / Design Principle:

The easy solution for thin wall tanks (0.635cm thick): ELS-1100FLG Series Level Switch. No threads needed with these flanged units. Slip through a 2.9cm hole and tighten the jam nut; Viton gasket forms a tight seal. Ideal for sheet metal, molded plastic tanks and medical applications where elimination of exposed threads removes potential bacterial breeding grounds.

ELS Series Level Switches are low cost, compact, optical level sensors with built-in switching electronics. With no moving parts, these small units are ideal for a variety of point level sensing applications especially where dependability and economy are a must.

Level switches are suitable for high, low or intermediate level detection in practically any tank top, large or small. Installation is simple and quick through the tank top, bottom or side. Solid state-switching ensures dependability over long service life.

The sensor offers ±1mm repeatability and broad liquid compatibility. They are not recommended for use in any liquid that crystallizes or leaves a solid residue. 
 

Applications:

  • Medical Laboratory
  • Food and Beverage Systems
  • Pharmaceuticals
  • Petrochemicals
  • Leak Detection
  • Hydraulic Reservoirs
  • Machine Tools

Specifications

Materials

Housing and Prism: Polysulfone

Operating Pressure

0 to 10 bar (0 to 150 psi), Maximum

Operating Temperature*

-17.8°C to +80°C (0°F to +176°F)

Input Voltage

10-28 VDC 

Current Consumption

18 mA, Approximately

Output

TTL/CMOS Compatible. Open Collector Output May Sink 40 mA up to 30 VDC

Repeatability

±1 mm

EMI Susceptibility

Meets (MIL-STD-461B Part 2 Modified) Specification of 10 V/M for Frequency Range 30 to 1000 MHz
(Except 609 MHz = 9 V/M and 679 MHz = 7.5 V/M)

*These switches are not for use in freezing liquid

 dimELS1100FLG.gif 

A  2.16" REF. 
B  1/8" Viton®Gasket. 
C  1/4" Max. Wall Thickness 
D  Lead Wires 
Additional Product Information: 
Typical Wiring Diagrams 
Simple Operating Principle 
Product Search