Direct Motor Load Control
Quick Specs...
- Solid State Reliability
- No Contactors
- 11 or 19K Ohms/cm Sensitivity
- Direct or Inverse Modes
- LED Indicator
- Spade Terminals for Easy Installation
- CSA Approved
- U.L. "Motor Control"
|
|
|
Overview / Design Principle:
Series 19MR controls are the ideal choice where pump up or pump down service is necessary. This control eliminates the need for contactors because it can directly handle motors up to 1 HP at 120 VAC, or motors up to 2 HP at 240 VAC.
Applications:
Carbonators
Appliances
Sumps
Low-Water Cutoff
Direct Motor Load
|
|
| Specifications |
Enclosures
|
Optional
|
Output Contact Rating
|
30 A @ 240 VAC
|
Powered Output Contact
|
SPST 30 A at supply voltage (120 or 240 VAC)
|
Horsepower Range
|
1 hp for 120 VAC; 2 hp for 240 VAC
|
Terminals
|
3/16" spade lug on probe connections
1/4" spade lug on power connections
|
Primary Voltage
|
120 VAC or 240 VAC (+10%/-15%), 50/60 Hz
|
Secondary Voltage
|
11.0 VAC, 1.5 mA
|
Temperature
|
-40°F to 150°F (-40°C to 65°C)
|
Approvals
|
U.L. 508 File # E44426, Vol. 1 Sec. 6
|
|
|
|
| A |
Keyhole & Slot for Two Size 6 Mounting Screws |
| B |
3-1/2" (8.9 cm) |
| C |
4" (10.16 cm) |
| D |
1-1/2" (3.8 cm) |
| E |
1-7/16" (3.7 cm) |
| F |
2-7/8" (7.3 cm) |
| G |
1-7/16" (3.7 cm) |
| H |
240V |
| I |
120V |
| J |
COM/L2 |
| K |
Load |
| L |
COM/L2 |
| M |
240V |
| N |
120V |
| O |
L |
| P |
H |
| Q |
G |
|
|
|
|
|