| Specifications |
Input
|
Pressure Range
|
Vacuum to 400 bar (6000 psi)
|
Proof Pressure
|
4 x Full Scale (FS) (<1% FS Zero Shift)
|
Burst Pressure
|
>35 x FS <= 4 bar (60 psi);
>20 x FS <= 40 bar (600 psi);
>5 x FS <= 400 bar (6000 psi)
|
Fatigue Life
|
Designed for more than 100 million FS cycles |
Performance
|
Supply Voltage Sensitivity
|
0.01% FS/Volt
|
Long Term Drift
|
0.2% FS/year (non-cumulative)
|
Accuracy
|
0.5% FS typical (optional 0.15% FS)
|
Thermal Error
|
2.0% FS typical
|
Compensated Temperatures
|
-20°F to 80°F (-5°C to 180°C)
|
Operating Temperatures
|
-40°C to 125°C (-22°F to 260°F) for elec. codes A, B, C, 1
-20° to 80°C (-5° to 180°F) for elec. codes 2, D, G, 3
-20° to 50 °C (-5° to 125°F) for elec. code F temperatures > 100°C supply is limited to 24 Vdc.
|
Zero Tolerance
|
1% span
|
Span Tolerance
|
1% span
|
Response Time
|
0.5 ms
|
Mechanical Configuration
|
Pressure Port
|
See ordering chart
|
Wetted Parts
|
17-4 PH Stainless Steel
|
Electrical Connection
|
See ordering chart
|
Enclosure
|
316 SS, 17-4 PH ss
IP65 for elec. codes A, B, C, D, G, 1, 2, 3
IP67 for elec. codes F
IP30 for elec. code "3" with flying leads
|
Vibration
|
70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 200 Hz @ =20g Peak per MIL-STD.-810E Method 514.4)
|
Acceleration
|
100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range
|
Shock
|
20g, 11 ms, per MIL-STD.810E
Method 516.4 Procedure I
|
Approvals
|
CE, ETL Intrinsically Safe for Class 1, Div. 1, Groups C & D (also available as BASEEFA ATEX intrinsically safe - contact factory for part numbers)
|
Weight
|
Approx. 100 grams (additional; cable 75 g/m)
|
| Voltage Output Units |
Output
|
See ordering chart
|
Supply Voltage (Vs)
|
1.5 Vdc above span to 35 Vdc
|
Min. Load Resistance
|
(FS output / 2) K Ohms
|
| Current Output Units |
Output
|
4-20 mA (2 wire)
|
Supply Voltage (Vs)
|
24 Vdc, (7-35 Vdc)
|
Max. Loop Resistance
|
(Vs-7) x 50 ohms
|
Electromagnetic Capability
Meets the requirement for CE marking of EN50081-2 for emissions and EN50082-2 for susceptibility.
Test Data:
• EN61000-4-2 Electrostatic Discharge. 8kV air discharge, 4kV contact discharge. Unit survived.
• ENV50140 Radiated RF Susceptibility. 10V/m, 80MHz-1GHz, 1kHz mod. Maximum recorded output error was <±1%
• ENV50204 Radiated RF Susceptibility to Mobile Telephones. 10V/m, 900MHz. Maximum recorded output error was <±1%.
• EN61000-4-4 Fast Burst Transient. 2kV, 5/50ns, 5kHz for 1 minute. Unit survived.
• ENV50141 Conducted RF Susceptibility. 10Vms, 1kHz mod, 150kHz - 80MHz. Maximum recorded output error was <±1%
|