|
Specifications
|
|
Input
|
|
Pressure Range
|
Vacuum to 400 bar (6000 psi)
|
|
Proof Pressure
|
4 x Full Scale (FS) (<1% FS Zero Shift)
|
|
Burst Pressure
|
>35 x FS <= 4 bar (60 psi);
>20 x FS <=40 bar (600 psi);
>5 x FS <=400 bar (6000 psi)
|
|
Fatigue Life
|
Designed for more than 100 million FS cycles
|
|
Performance
|
|
Supply Voltage Sensitivity
|
0.01% FS/Volt
|
|
Long Term Drift
|
0.2% FS/year (non-cumulative)
|
|
Accuracy
|
0.5 % FS typical (optional 0.15% FS)
|
|
Thermal Error
|
2.0% FS typical
|
|
Compensated Temperatures
|
-20°C to 80°C (-5°F to 180°F)
|
|
Operating Temperatures
|
-40°C to 125°C (-22°F to 260°F) for elec. codes C, 1
-20° to 80°C (-5° to 180°F) for elec. codes G, 3
|
|
Zero Tolerance
|
1% of span
|
|
Span Tolerance
|
1% of span
|
|
Response Time
|
0.5 ms
|
|
Mechanical Configuration
|
|
Pressure Port
|
See ordering chart
|
|
Wetted Parts
|
17-4 PH Stainless Steel
|
|
Electrical Connection
|
See ordering chart
|
|
Enclosure
|
316 SS, 17-4 PH ss
IP65 for elec. codes C, G, 1, 3
IP30 for elec. code "3" with flying leads
|
|
Vibration
|
70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 200 Hz @ =20g Peak per MIL-STD.-810E Method 514.4)
|
|
Acceleration
|
100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range.
|
|
Shock
|
20g, 11 ms, per MIL-STD.-810E
Method 516.4 Procedure l
|
|
Approvals
|
CE, UR (12 ET, 16 ET Intrinsically safe)
|
|
Weight
|
approx. 100 grams (additional; cable 75 g/m)
|
|
Voltage Output Units
|
|
Output
|
See ordering chart
|
|
Supply Voltage (Vs)
|
1.5 Vdc above span to 35 Vdc
|
|
Min. Load Resistance
|
(FS output / 2) K ohms
|
|
Current Output Units
|
|
Output
|
4-20 mA (2 wire)
|
|
Supply Voltage (Vs)
|
24 Vdc, (7-35 Vdc)
|
|
Max. Load Resistance
|
(Vs-7) x 50 ohms
|
Notes:
1. When electrical connection is DIN or plug style “U” must be specified.
2. Electrical Connections “F” and “2” are 24AWG, Shielded, PVC Cable.
3. Additional Pressure Ranges are available. Please consult factory.
4. Intrinsically safe transducers are available with amplified outputs only. (ETL, entity approved for Class I, Division 1, Groups C & D, hazardous areas).
Electromagnetic Capability
Meets the requirement for CE marking of EN50081-2 for emissions and EN50082-2 for susceptibility.
Test Data:
• EN61000-4-2 Electrostatic Discharge. 8kV air discharge, 4kV contact discharge. Unit survived.
• ENV50140 Radiated RF Susceptibility. 10V/m, 80MHz-1GHz, 1kHz mod. Maximum recorded output error was <±1%
• ENV50204 Radiated RF Susceptibility to Mobile Telephones. 10V/m, 900MHz. Maximum recorded output error was <±1%.
• EN61000-4-4 Fast Burst Transient. 2kV, 5/50ns, 5kHz for 1 minute. Unit survived.
• ENV50141 Conducted RF Susceptibility. 10Vms, 1kHz mod, 150kHz - 80MHz. Maximum recorded output error was <±1%
|