| Specifications: |
Max. Flow
|
12 l/min
|
Max. Operating Pressure
|
68 bar
|
Proof Pressure
|
100 bar
|
| Temperature Range |
- with Polysulfone piston (standard), with cable, with plug connector: -20°C to +80°C - with metal piston and terminal box: -20°C to +150°C |
| Set Points (l/min) |
0.4; 1.0; 2.0; 3.0; 4.0; 6.0 |
Switching Function (related to increasing flow)
|
NC, NO, SPDT
|
| Mounting Position |
any position |
| Factory Mounting Position with Set Point Adjustment |
vertical, inlet port down, electrical connection up |
| Repeatability |
± 1% |
Adjustment Accuracy
|
± 10%
|
Hysteresis
|
max. 15%
|
Mounting
|
G 1/4"
|
Electrical Connections
|
- cable: PVC, 2 or 3 x 0.34 mm2 (length: approx. 1m) - plug connector per DIN 43650 - terminal box
|
Enclosure
|
- IP 65
|
Electrical Data Contact Rating
|
- SPST (NC/NO): max. 100 VA, 3 A, 220 V~ - SPDT: max. 20 VA, 0.5 A, 250 V~
|
Weight
|
0.5 kg
|
Approvals
|
CE
|
IMPORTANT REED SWITCH PROTECTION INFORMATION: Read before installing.
Switches are U.L. Approved for Class I, Division 2, Groups A, B, C, D hazardous areas. They are also available with FM-approved explosion-proof junction box for Class I, Division 1, Group D hazardous loactions. Units must be completely assembled at Gems.
| Flow Settings, Air (Typical) Dependent on operating line pressure. Examples of set point ranges at a given line pressure are shown below. |
Line Pressure
|
Actuation Point |
FS-925
|
FS-926
|
M"
|
Max.
|
M"
|
Max.
|
5 PSIG (Minimum)
|
0.5 SCFM
|
10 SCFM
|
2 SCFH
|
15 SCFH
|
100 PSIG
|
1.5 SCFM
|
25 SCFM
|
7 SCFH
|
50 SCFH
|
Gas Calibration Water flow units should not be used for air/gas applications: Gas flow units have a special dash-pot piston for reliable operation. Gas calibration is dependent upon line pressure, switch orientation, and the specific type of gas. The calibrated flow set point is subject to change with fluctuations in line pressure.
|