Gems Sensors Spacer
Message
 
Loading...
ELS-1100TFE Series

Teflon For Ultra-Pure or Aggressive Fluids 

ELS-1100TFE Series

Quick Specs...

  • Small Size
  • Economically Priced
  • Built-in, Solid-State Electronics
  • No Moving Parts
  • Simple, One-Unit Installation


Overview Specifications Dimensions Related Info  

Overview / Design Principle:

When high purity or resistance to chemical attack is vital, ELS-1100TFE sensors are the ultimate solution. They feature a pure Teflon body and prism construction. Even the Hypalon vapor barrier and Teflon coated lead wires give evidence to the care we've taken to make the perfect liquid level sensors for pharmaceuticals, semiconductor manufacturing, food and beverage, chemical processing, or anywhere purity or chemical resistance is the major criteria.

ELS Series Level Switches are low cost, compact, optical, level sensors with built-in switching electronics. With no moving parts, these small units are ideal for a variety of point level sensing applications especially where dependability and economy are a must.

Level switches are suitable for high, low or intermediate level detection in practically any tank top, large or small. Installation is simple and quick through the tank top, bottom or side. Solid state-switching ensures dependability over long service life.

The sensor offers ±1mm repeatability and broad liquid compatibility. They are not recommended for use in any liquid that crystallizes or leaves a solid residue.

Applications:

  • Medical Laboratory
  • Food and Beverage Systems
  • Pharmaceuticals
  • Petrochemicals
  • Leak Detection
  • Hydraulic Reservoirs
  • Machine Tools

Specifications:

Materials

Housing and Prism; Teflon

Operating Pressure

0 to 10 bar (0 to 150 PSI), Maximum  

Operating Temperature*

-17.8°C +80°C (0°F to 176°F) 

Current Consumption

18 mA, Approximately

Output

TTL/CMOS Compatible. Open Collector Output May Sink 40 mA up to 30 VDC

Input Voltage

10-28 VDC  

Repeatability

±1 mm 

EMI Susceptibility

Meets (MIL-STD-461B Part 2 Modified) Specification of 10 V/M for Frequency Range 30 to 1000 MHz = (Except 609 MHz = 9 V/M and 679 MHz = 7.5 V/M) 

*These switches are not intended for use in freezing liquids or steam/high condensation environments. Contact GEMS for alternative solutions if these environments exist.

 HT Series
 DimELS1100TFE.gif
A 2 1/2" REF.
B .50" REF.
C 1/4" NPT REF.
D 5/8" HEX. REF.
E Optional Hypalon® Boot, Cable Seal
F 3/8" NPT Conduit Connection
G Cable, TFE Jacket
Additional Product Information:
Typical Wiring Diagrams
Simple Operating Principle
Product Search